API src

Found 12744 results.

Similar terms

s/ctu/Cu/gi

Other language confidence: 0.7486687767519078

Measured environmental concentrations of copper and hazard quotients in the German Bight in summer from 1986 to 2021

Data includes the measured environmental concentrations (MEC) of the summer copper (Cu) concentration in the German Bight from 1986 to 2021 (MUDAB database, https://geoportal.bafg.de/MUDABAnwendung/), including sampling points coordinates, year of sampling and Cu concentration. Additionally the Hazard quotient (HQ) is provided by dividing the MEC with the predicted no effect concentration (PNEC), defined as EC10 estimates from Crassostrea gigas embryos exposed for 48 h at 18°C and LC10 estimates from C. gigas larvae exposed for 24 h at 24°C, divided by an assessment factor (AF) of 5.

Raw data of physical oceanography during RV HEINCKE cruise HE663

Raw physical oceanography data was acquired by a ship-based Seabird SBE911plus CTD-Rosette system onboard RV HEINCKE . The CTD was equipped with duplicate sensors for temperature (SBE3plus) and conductivity (SBE4) as well as one sensor for oxygen (SBE43). Additional sensors such as a WET Labs C-Star transmissometer, a WET Labs ECO-AFL fluorometer (FLRTD) and an altimeter (Teledyne Benthos PSA-916) were mounted to the CTD. The data was recorded using pre-cruise calibration coefficients. No correction, post-cruise calibration or quality control was applied. Processed profile data are available via the link below.

Steigerung der Ressourceneffizienz in PV-Kraftwerken, Teilvorhaben: Technologieverbesserung der Wickelgüter (TechnoWickel)

In diesem Vorhaben soll daher ein ganzheitliches Konzept deutliche Ressourcen- und Kostenersparnissen für große PV-Kraftwerke (>5 MW) im Detail entwickelt und im Labormaßstab (TRL 5) verifiziert werden. Im Vorhaben soll daher der Fokus auf die Wechselrichter und weitere Balance-of-System (BOS)-Komponenten gelegt werden. Nach Auswahl des geeignetsten Konzeptes soll ein Demonstrator eines Wechselrichters und eines aktiven Combiners entsprechend den Spezifikationen entwickelt und aufgebaut werden, der anschließend im Labormaßstab evaluiert wird. Der im Vorhaben adressierte Konzeptansatz beinhaltet Insbesondere die folgenden sieben Ansatzpunkte und Projektziele: - Einsparungen von Kabeln im Kraftwerk um 75 % - Einsparungen im Kühlkörper um 20 % - Kosteneffizientes Integrationspotenzial von PV+X Kraftwerken - Reduzierung der Stromgestehungskosten - Einsparungen von Kupfer und Ferrit in Wickelgütern - Integration von Analysefunktionen im Combiner - Einsparungen von Schutzelementen im Kraftwerk

Grundwassermessstelle DEGM_DENW_100120015: BS 1 KNETTERHDE

Stammdaten und Analysedaten zu den Grundwassermessstellen im EUA-Messnetz: Messtelle DEGM_DENW_100120015 (BS 1 KNETTERHDE)

Messstelle 3064 I Waldmohr (Messstellen-Nr: 2546134300)

Die Messstelle 3064 I Waldmohr in Rheinland-Pfalz dient der Überwachung von Grundwasserstände. Zeitreihen abiotische Parameter werden derzeit nicht gemessen.

Messstelle 3056 Cronenberg (Messstellen-Nr: 2546120800)

Die Messstelle 3056 Cronenberg in Rheinland-Pfalz dient der Überwachung von Grundwasserstände. Zeitreihen abiotische Parameter werden derzeit nicht gemessen.

WMS MSRL: D8-Schadstoffe (sh-llur), Mittelwert 2005-2010

Der WMS umfasst Schadstoffe im Wasser und im Sediment, die an Messstationen des LLUR erfasst werden. Parameter: Quecksilber, Blei, Kupfer, Nickel, Arsen, Cadmium, Chrom, Zink.

Continuous recordings of environmental parameters at station 17, Sagasbank (2023-10 - 2024-09)

Additionally, at four shallow water stations (Booknis Eck, Buelk, Behrensdorf and Katharinenhof) temperature, salinity and dissolved oxygen are continuously logged at 2-3 m depth by self-contained data loggers. These are: (I) MiniDOT loggers (Precision Measurement Engineering; http://pme.com; ±10 µmol L-1 or ±5 % saturation) including copper antifouling option (copper plate and mesh) to measure dissolved oxygen concentration and (II) DST CT salinity & temperature loggers (Star-Oddi; http://star-oddi.com; ±1.5 mS cm-1) to record the conductivity. Both sensor types additionally record water temperature with an accuracy of ± 0.1 °C. The sampling interval was set to 30 minutes for all parameters. In context of the long-term monitoring project RegLocDiv (Regional-Local-Diversity) by M. Wahl (Franz, M. et al. 2019a), another seven stations were equipped with the same two types of sensors at 4-6 m depth to continuously record environmental parameters (again: temperature, salinity, dissolved oxygen) and included into this data set. These stations are at: Falshoeft, Booknis Eck, Schoenberg, Westermarkelsdorf, Staberhuk, Kellenhusen and Salzhaff (abandoned in 2023). Since 2021, in the context of implementing a reef monitoring to fulfil obligations by the EU Habitats Directive, step-by-step, eleven further stations were installed at reefs in the Schleswig-Holstein Baltic Sea. These are at: Platengrund (14 m depth) and Mittelgrund (8 m) (both since 2021), at Walkyriengrund (9 m), Brodtener Ufer (8 m), Außenschlei (11 m), Kalkgrund (8 m), Stollergrund (7.5 m) and Flueggesand (10 m) (all since 2022), as well as at Gabelsflach (10 m), Sagasbank (8.5 m) and Stabehuk (11.5 m) (all since 2023). Again, at all of these 11 stations, temperature, salinity and dissolved oxygen are continuously logged by self-contained data loggers: Conductivity (and temperature) is logged by HOBO® Salt Water Conductivity/Salinity Data Logger (Onset Computer Corporation, Bourne, MA, USA; https://www.onsetcomp.com) using the U2X protective housing to prevent fouling on the sensors. The same MiniDOT loggers (Precision Measurement Engineering) as at the above mentioned more shallow stations (including antifouling copper plate and mesh) are used to measure dissolved oxygen concentration. Dissolved oxygen concentration data measured by the MiniDOT loggers are corrected for a depth of 10 m (or 2,5 m on the shallow stations) using the software provided by the manufacturer. Additionally, a manual compensation for salinity was calculated (see details in Franz, M. et al. 2019b). Quality control was carried out by spike and gradient tests, following recommendations of SeaDataNet quality control procedures (see https://seadatanet.org/Standards/Data-Quality-Control). All data values were flagged according to applied quality checks using the following flags: 1 = Pass, 2 = Suspect, 3 = Fail, 4 = Visually suspect, 5 = Salinity compensation fail (further explanations can be found in Franz, M. et al. 2019b).

Continuous recordings of environmental parameters at station 19, Brodtener_Ufer (2022-09 - 2024-09)

Additionally, at four shallow water stations (Booknis Eck, Buelk, Behrensdorf and Katharinenhof) temperature, salinity and dissolved oxygen are continuously logged at 2-3 m depth by self-contained data loggers. These are: (I) MiniDOT loggers (Precision Measurement Engineering; http://pme.com; ±10 µmol L-1 or ±5 % saturation) including copper antifouling option (copper plate and mesh) to measure dissolved oxygen concentration and (II) DST CT salinity & temperature loggers (Star-Oddi; http://star-oddi.com; ±1.5 mS cm-1) to record the conductivity. Both sensor types additionally record water temperature with an accuracy of ± 0.1 °C. The sampling interval was set to 30 minutes for all parameters. In context of the long-term monitoring project RegLocDiv (Regional-Local-Diversity) by M. Wahl (Franz, M. et al. 2019a), another seven stations were equipped with the same two types of sensors at 4-6 m depth to continuously record environmental parameters (again: temperature, salinity, dissolved oxygen) and included into this data set. These stations are at: Falshoeft, Booknis Eck, Schoenberg, Westermarkelsdorf, Staberhuk, Kellenhusen and Salzhaff (abandoned in 2023). Since 2021, in the context of implementing a reef monitoring to fulfil obligations by the EU Habitats Directive, step-by-step, eleven further stations were installed at reefs in the Schleswig-Holstein Baltic Sea. These are at: Platengrund (14 m depth) and Mittelgrund (8 m) (both since 2021), at Walkyriengrund (9 m), Brodtener Ufer (8 m), Außenschlei (11 m), Kalkgrund (8 m), Stollergrund (7.5 m) and Flueggesand (10 m) (all since 2022), as well as at Gabelsflach (10 m), Sagasbank (8.5 m) and Stabehuk (11.5 m) (all since 2023). Again, at all of these 11 stations, temperature, salinity and dissolved oxygen are continuously logged by self-contained data loggers: Conductivity (and temperature) is logged by HOBO® Salt Water Conductivity/Salinity Data Logger (Onset Computer Corporation, Bourne, MA, USA; https://www.onsetcomp.com) using the U2X protective housing to prevent fouling on the sensors. The same MiniDOT loggers (Precision Measurement Engineering) as at the above mentioned more shallow stations (including antifouling copper plate and mesh) are used to measure dissolved oxygen concentration. Dissolved oxygen concentration data measured by the MiniDOT loggers are corrected for a depth of 10 m (or 2,5 m on the shallow stations) using the software provided by the manufacturer. Additionally, a manual compensation for salinity was calculated (see details in Franz, M. et al. 2019b). Quality control was carried out by spike and gradient tests, following recommendations of SeaDataNet quality control procedures (see https://seadatanet.org/Standards/Data-Quality-Control). All data values were flagged according to applied quality checks using the following flags: 1 = Pass, 2 = Suspect, 3 = Fail, 4 = Visually suspect, 5 = Salinity compensation fail (further explanations can be found in Franz, M. et al. 2019b).

Continuous recordings of environmental parameters at station 13, Platengrund (2021-09 - 2024-09)

Additionally, at four shallow water stations (Booknis Eck, Buelk, Behrensdorf and Katharinenhof) temperature, salinity and dissolved oxygen are continuously logged at 2-3 m depth by self-contained data loggers. These are: (I) MiniDOT loggers (Precision Measurement Engineering; http://pme.com; ±10 µmol L-1 or ±5 % saturation) including copper antifouling option (copper plate and mesh) to measure dissolved oxygen concentration and (II) DST CT salinity & temperature loggers (Star-Oddi; http://star-oddi.com; ±1.5 mS cm-1) to record the conductivity. Both sensor types additionally record water temperature with an accuracy of ± 0.1 °C. The sampling interval was set to 30 minutes for all parameters. In context of the long-term monitoring project RegLocDiv (Regional-Local-Diversity) by M. Wahl (Franz, M. et al. 2019a), another seven stations were equipped with the same two types of sensors at 4-6 m depth to continuously record environmental parameters (again: temperature, salinity, dissolved oxygen) and included into this data set. These stations are at: Falshoeft, Booknis Eck, Schoenberg, Westermarkelsdorf, Staberhuk, Kellenhusen and Salzhaff (abandoned in 2023). Since 2021, in the context of implementing a reef monitoring to fulfil obligations by the EU Habitats Directive, step-by-step, eleven further stations were installed at reefs in the Schleswig-Holstein Baltic Sea. These are at: Platengrund (14 m depth) and Mittelgrund (8 m) (both since 2021), at Walkyriengrund (9 m), Brodtener Ufer (8 m), Außenschlei (11 m), Kalkgrund (8 m), Stollergrund (7.5 m) and Flueggesand (10 m) (all since 2022), as well as at Gabelsflach (10 m), Sagasbank (8.5 m) and Stabehuk (11.5 m) (all since 2023). Again, at all of these 11 stations, temperature, salinity and dissolved oxygen are continuously logged by self-contained data loggers: Conductivity (and temperature) is logged by HOBO® Salt Water Conductivity/Salinity Data Logger (Onset Computer Corporation, Bourne, MA, USA; https://www.onsetcomp.com) using the U2X protective housing to prevent fouling on the sensors. The same MiniDOT loggers (Precision Measurement Engineering) as at the above mentioned more shallow stations (including antifouling copper plate and mesh) are used to measure dissolved oxygen concentration. Dissolved oxygen concentration data measured by the MiniDOT loggers are corrected for a depth of 10 m (or 2,5 m on the shallow stations) using the software provided by the manufacturer. Additionally, a manual compensation for salinity was calculated (see details in Franz, M. et al. 2019b). Quality control was carried out by spike and gradient tests, following recommendations of SeaDataNet quality control procedures (see https://seadatanet.org/Standards/Data-Quality-Control). All data values were flagged according to applied quality checks using the following flags: 1 = Pass, 2 = Suspect, 3 = Fail, 4 = Visually suspect, 5 = Salinity compensation fail (further explanations can be found in Franz, M. et al. 2019b).

1 2 3 4 51273 1274 1275