Untersuchungen zu umweltbedingten Erkrankungen bei Studierenden unter besonderer Beruecksichtigung ihrer Wohn- und Arbeitssituation

Im Rahmen der an der Universitaet Bielefeld mit dem WS 96/97 beginnenden Gesundheitsberatung fuer Studierende wird vom Gesundheitslabor eine umweltorientierte Gesundheitsberatung angeboten. Die Beratung wird in Bezug auf umweltrelevante Erkrankungen mit dem Schwerpunkt indoor-Gifte evaluiert werden. In Hinsicht auf den durch indoor-Gifte vermutlich ausgeloesten Formenkreis von Erkrankungen, zu denen das Sick-building-Syndrom und das Multiple-chemical-sensitivity-Syndrom gerechnet werden, soll eine Population von betroffenen Studenten biomedizinisch (Spirometrie, Biomass-Index) und immunologisch-physiologisch (weisses Blutbild, Leukozytensubpopulation, Cotininbestimmung, Monooxidase-Aktivitaet, Stressfaktoren) sowie mit Hilfe des Biomonitorings im Vergleich zu einer Kontrollgruppe untersucht werden. Das Spektrum der moeglichen Ausloeserfaktoren dieser Erkrankungen soll auf sozio-oekonomische und psychische Faktoren unter Verwendung eines Fragebogens erweitert werden. Ziel des Projektes ist es, weitere Erkenntnisse ueber die Ursachen des Formenkreises Sick-building-Syndrom/Multiple-chemical-sensitivity-Syndrom zu gewinnen.

Nanotechnology based intelligent multi-SENsor System with selective pre-concentration for Indoor air quality control (SENSIndoor)

SENSIndoor aims at the development of novel nanotechnology based intelligent sensor systems for selective monitoring of Volatile Organic Compounds (VOC) for demand controlled ventilation in indoor environments. Greatly reduced energy consumption without adverse health effects caused by the Sick Building Syndrome requires optimized ventilation schemes adapted to specific application scenarios like offices, hospitals, schools, nurseries or private homes. - SENSIndoor will measure the quality of indoor air. - SENSIndoor will develop smart, energy efficient ventilation systems. - SENSIndoor will bring forth demand controlled ventilation - the key for energy efficient buildings. - SENSIndoor will develop novel nanotechnology-based microsensor systems for room specific ventilation.

Cost-Effective Tools for Better Indoor Environment in Retrofitted Energy Efficient Buildings (CETIEB)

Objective: The refurbishing to an energy efficient standard leads to tight buildings (whole envelope: windows, walls, etc.) and affects the indoor climate. In case of refurbishing the inhabitants or users are not adapted to this new situation. Therefore the air exchange rates could be lower than required if no mechanical ventilation is installed or the system performance is not optimised. Then, in trying to increase the energy performance of buildings, the indoor environment quality is often degraded due to the lack of exchange with the outdoor environment. People in Europe spend more than 90 Prozent of their time indoors (living, working, and transportation). In more than 40 Prozent of the enclosed spaces, people suffer from health- and comfortable related complains and illness. Already in 1984 the WHO reported an increased frequency in buildings with indoor climate problems. The complexity of the problem and the fact of building related symptom clusters were later described as Sick Building Syndrome. The main objective of the project is to develop innovative solutions for better monitoring the indoor environment quality and to investigate active and passive systems for improving it. The focus lies on cost-effective solutions to ensure a wide application of the developed systems. The project is based on three main objectives: - Development of monitoring systems (wireless and/or partly wired) to detect insufficient comfort and health parameter. It is foreseen to develop a modular version for allowing normal end users making a quick check of the indoor air quality. - Development of control systems for indoor environments which could be based on passive elements like cost effective photo catalytic materials or PCMs and active systems which control the air flow rates based on the monitoring data. - Modelling of indoor environments for the assessment and validation of monitoring data and to optimise with respect to energy efficiency the control parameters and systems.

Indoor air pollution, physical and comfort parameters related to schoolchildren's health: Data from the European SINPHONIE study

Substantial knowledge is available on the association of the indoor school environment and its effect among schoolchildren. In the same context, the SINPHONIE (School indoor pollution and health: Observatory network in Europe) conducted a study to collect data and determine the distribution of several indoor air pollutants (IAPs), physical and thermal parameters and their association with eye, skin, upper-, lower respiratory and systemic disorder symptoms during the previous three months. Finally, data from 115 schools in 54 European cities from 23 countries were collected and included 5175 schoolchildren using a harmonized and standardized protocol. The association between exposures and the health outcomes were examined using logistic regression models on the environmental stressors assessed in classroom while adjusting for several confounding factors; a VOC (volatile organic compound) score defined as the sum of the number of pollutants to which the children were highly exposed (concentration > median of the distribution) in classroom was also introduced to evaluate the multiexposure - outcome association. Schoolchildren while adjusting for several confounding factors. Schoolchildren exposed to above or equal median concentration of PM2.5, benzene, limonene, ozone and radon were at significantly higher odds of suffering from upper, lower airways, eye and systemic disorders. Increased odds were also observed for any symptom (sick school syndrome) among schoolchildren exposed to concentrations of limonene and ozone above median values. Furthermore, the risks for upper and lower airways and systemic disorders significantly increased with the VOCs score. Results also showed that increased ventilation rate was significantly associated with decreased odds of suffering from eye and skin disorders whereas similar association was observed between temperature and upper airways symptoms. The present study provides evidence that exposure to IAPs in schools is associated with various health problems in children. Further investigations are needed to confirm our findings. © 2020 Elsevier B.V.

Innenraumbelastung durch Holzschutzmittel; Dampfdruckmessungen als Beitrag zur verbesserten Abschaetzung maximal moeglicher Raumluftkonzentrationen

Dampfdruckmessungen am Holzschutzmittelwirkstoff Dichlofluanid dienen zur Abschaetzung der maximal auftretenden Raumluftkonzentrationen. Versuche dazu erfolgen in Klimakammern.

Biokybernetische Aspekte im Siedlungswesen

Das Regulationssystem von Mensch, Tier und Pflanze wird von informationstragenden Mikroenergien im CM-Wellenlaengenbereich gesteuert. In diesem Wellenlaengenbereich gelten die Gesetze der Akustik und der Optik, sowie die Prinzipien der Resonanz. Diese Schwingungen treten links- oder rechtszirkular auf und haben unterschiedlich biologische Wirkung. Emittenten sind das terrestrische Abstrahlungsvermoegen des Magma der Erde. Durch Anomalien in der Erdkruste ergeben sich Strahlungsverdichtungen mit verstaerkender Wirkung. Weitere Emittenten kommen aus dem Kosmos und aus technischen Anlagen. Die Baugeschichte verwendete diese biokybernetisch wirkenden Strahlungsphaenomene verstaerkend oder - je nach Bedarf - daempfend, umpolarisierend oder feldveraendernd. Das hat Konsequenzen fuer die heutige Stadtplanung und Architektur. Messtechnische Untersuchungen sind kaum moeglich, da die Intensitaeten weit unterhalb des Rauschpegels angesiedelt sind. Durch Hautwiderstandsmessungen und durch abstimmbare Antennen mit dem nachgeschalteten Empfaenger Mensch lassen sich jedoch die Regulationsfrequenzen ermitteln.

Sick-Building-Syndrom. Ueber den Umfang mit informationstragenden Mikroenergien (IME) Zusammenhaenge - Ursachen - Selbsthilfe

Luftfilter als Quelle fuer gesundheitsbelastende Endotoxine in raumlufttechnischen Anlagen

Es wird angenommen, dass die Bildung und Freisetzung von Endotoxinen in raumlufttechnischen (RU-) Anlagen mitverantwortlich ist fuer das Auftreten des 'Sick Building Syndroms' in kuenstlich beluefteten Innenraeumen. Im Rahmen des Forschungsprojekts soll geklaert werden, ob bzw in welchem Masse Endotoxine in RLT-Anlagen - speziell im Bereich von Luftfiltern und Befeuchtern - gebildet werden und ob die Endotoxinkonzentrationen in RLT-Anlagen in 'Sick Buildings' hoeher ist, als in sog 'Healthy buildings'. Zur Klaerung dieser Fragestellung werden durch 2 zeitlich um ein halbes Jahr versetzt beginnenden 1-Jahres- Versuchsreihen in jeweils 3 Gebaeuden in je 1 RLT-Anlage die Endotoxin-Konzentrationen vor, auf und hinter den Luftfiltern sowie vor und hinter den Befeuchteranlagen messtechnische bestimmt. Die Gebaeude unterscheiden sich ua durch das seltene ('healthy') bzw haeufige ('sick') Beklagen gesundheitlicher Beschwerden.

Hygienische Untersuchungen zur Bestimmung der maximal zulaessigen Staubbelegung von Zuluftkanaelen in Klimaanlagen

Beim Betrieb von raumlufttechnischen (RU-)Anlagen werden auf der Oberflaeche von Lueftungskanaelen belebte (Mikroorganismen) und unbelebte (Staub) Partikel abgeschieden und reichern sich dort an. Um den Einfluss dieser 'Verschmutzung' der Lueftungskanaele auf die Qualitaet der Zuluft von RLT-Anlagen zu ermitteln wurde im Rahmen erster orientierender Untersuchungen die Konzentration an belebten und unbelebten Partikeln in der Luft vor, in und nach den Zuluftkanaelen, sowie auf deren Oberflaeche bestimmt.

Standardisierung von Untersuchungen bei Exposition der Allgemeinbevoelkerung gegenueber niedrig konzentrierten Gefahrstoffgemischen in der Umwelt

Es bestehen gegenwaertig keine einheitlichen und standardisierten Untersuchungsverfahren, um die Wirkung niedrig konzentrierter Gefahrstoffgemische aus der Umwelt auf die Gesundheit der Allgemeinbevoelkerong hinlaenglich sicher zu erfassen. Damit fehlt suche die Grundlage fuer die Einrichtung gesundheitsbezogener umweltrelevanter Grenzwerte. Mit bisher fraglichem Erfolg werden Untersuchungen zu verschiedenen Problemen durchgefuehrt, z. B. Sick-Building-Syndrom, Verkehrsemissionen, Industrieimmissionen u.a.. Ziel des Projekts ist die Zusammenstellung der derzeitig praktizierten Untersuchungsverfahren und deren Pruefung auf Praezision, Richtigkeit sowie Praktikabilitaet. Das Ziel soll die qualitative und quantitative Vergleichbarkeit der erhobenen Daten sein. Hierzu werden die erforderlichen Mindeststandards erarbeitet.