API src

Found 1861 results.

Similar terms

s/spectrometer/Spektrometer/gi

METOP GOME-2 - Ozone (O3) - Global

The Global Ozone Monitoring Experiment-2 (GOME-2) instrument continues the long-term monitoring of atmospheric trace gas constituents started with GOME / ERS-2 and SCIAMACHY / Envisat. Currently, there are three GOME-2 instruments operating on board EUMETSAT's Meteorological Operational satellites MetOp-A, -B, and -C, launched in October 2006, September 2012, and November 2018, respectively. GOME-2 can measure a range of atmospheric trace constituents, with the emphasis on global ozone distributions. Furthermore, cloud properties and intensities of ultraviolet radiation are retrieved. These data are crucial for monitoring the atmospheric composition and the detection of pollutants. DLR generates operational GOME-2 / MetOp level 2 products in the framework of EUMETSAT's Satellite Application Facility on Atmospheric Chemistry Monitoring (AC-SAF). GOME-2 near-real-time products are available already two hours after sensing. The operational ozone total column products are generated using the algorithm GDP (GOME Data Processor) version 4.x integrated into the UPAS (Universal Processor for UV / VIS Atmospheric Spectrometers) processor for generating level 2 trace gas and cloud products. The new improved DOAS-style (Differential Optical Absorption Spectroscopy) algorithm called GDOAS, was selected as the basis for GDP version 4.0 in the framework of an ESA ITT. GDP 4.x performs a DOAS fit for ozone slant column and effective temperature followed by an iterative AMF / VCD computation using a single wavelength. For more details please refer to relevant peer-review papers listed on the GOME and GOME-2 documentation pages: https://atmos.eoc.dlr.de/app/docs/

Laseranwendungen

Laseranwendungen Aus den Eigenschaften der Laserstrahlung ergeben sich die verschiedensten Anwendungsmöglichkeiten: Anwendungen in der Technik Anwendungen im Alltag Anwendungen in der Technik Fertigungstechnik In der Fertigungstechnik macht man sich beim Bearbeiten verschiedener Materialien vor allem die hohe Leistungsdichte und die sehr starke Bündelung des Laserstrahls zunutze. Damit wird ein punktgenaues Bearbeiten der Werkstücke zum Beispiel beim Schweißen, Schneiden, Bohren, Löten oder Abtragen möglich. Eingesetzt werden dafür Laser mit Leistungen bis in den Kilowattbereich. Messtechnik In der Messtechnik werden Laser geringer Leistung für hochpräzises berührungsfreies Messen eingesetzt. Die Anwendungsgebiete sind sehr vielfältig: Messung von Entfernungen, Geschwindigkeiten, Materialdicken, Oberflächenprofilen, Abweichungen von vorgegebenen Führungslinien (zum Beispiel beim Tunnelbau) und so weiter. Von besonderer Bedeutung ist dabei die Kohärenz der verwendeten Strahlung . Spektroskopie Eine sehr spezielle Anwendung in der Forschung und in der chemischen Analytik ist die Spektroskopie. Dabei werden Stoffe und Stoffgemische aufgrund ihrer unterschiedlichen Strahlungsabsorption charakterisiert und bestimmt. Hierfür werden bevorzugt Farbstofflaser eingesetzt. Diese enthalten in Alkohol oder Wasser gelöste organische Farbstoffe. Sie sind je nach verwendetem Farbstoff in einem größeren Wellenlängenbereich "durchstimmbar". Mit unterschiedlichen Farbstoffen kann dabei ein Wellenlängenbereich von 300 bis 1200 Nanometer (das heißt vom UV -Bereich über das sichtbare Licht bis in den Infrarotbereich) abgedeckt werden. Hologramme Für die Herstellung von Hologrammen mit Hilfe von Laserstrahlung spielt die hohe Kohärenz des Laserlichts die wichtigste Rolle. Hologramme findet man auf EC- und Kreditkarten, aber auch als Aufkleber, Postkarten et cetera. Sie zeichnen sich dadurch aus, dass beim Betrachten ein dreidimensionales Bild zu sehen ist, das sich je nach Betrachtungswinkel verändert. Die bedeutendere Anwendung der Holographie findet sich in der Messtechnik und in der Datenverarbeitung. Anwendungen im Alltag Informations- und Kommunikationstechnik Am bekanntesten ist die Verwendung von Laserstrahlung in Laserdruckern, in CD-, beziehungsweise DVD-Laufwerken oder in Laserscannern, zum Bespiel bei der Warenerfassung an Kassen. In diesem Bereich werden häufig Halbleiterlaser, auch als Diodenlaser bezeichnet, eingesetzt. Die besonderen Vorteile der Halbleiterlaser bestehen in der direkten Anregung des Lasermediums durch elektrischen Strom, der guten Modulierbarkeit (das heißt man kann mit dem Laserstrahl sehr gut und sehr schnell Daten übertragen), einem relativ hohen Wirkungsgrad (das heißt die eingesetzte Energie wird zu einem relativ hohen Prozentsatz in Laserlicht umgesetzt extrem geringen Abmessungen, Robustheit und relativ langer Lebensdauer. Bei der Datenübertragung macht man sich neben der guten Modulierbarkeit der Laserstrahlung die Tatsache zunutze, dass die Strahlung sehr gut in Glasfaserkabeln weiterzuleiten ist. Laserpointer Laserpointer sind allgegenwärtig als handlicher optischer Zeigestab bei Präsentationen. Handelsübliche Laserpointer emittieren in den meisten Fällen sichtbares Licht der Farben Rot (Wellenlängen 630 nm – 780 nm), Grün (meist 532 nm) oder Blau (Wellenlängen 400 – 490 nm). Laserpointer als Verbraucherprodukte gehören in der Regel den niedrigen Laserklassen 1 oder 2 an. Auf entsprechende Kennzeichnung sollte geachtet werden. Auch für diese Laser gilt jedoch: Den Strahl nicht auf die Augen richten, beziehungsweise nicht in den Strahl schauen! Lasershow Lasershows erfreuen sich großer Beliebtheit in der Werbung und in der Unterhaltungsbranche. Mit Lasern können bewegte Muster und Bilder auf Wände projiziert werden. In Diskotheken werden bei Lasershows Laserstrahlen in den Raum projiziert und dadurch faszinierende Effekte erzeugt. Um die Besucher nicht zu gefährden, ist die Einhaltung der Sicherheitsvorschriften (siehe Schutzmaßnahmen ) besonders wichtig. Stand: 14.03.2024

Stationäre Feldspektrometermessungen

Processed stationary field spectroscopy measurementes. Time series were collected with solar powered long-term installations (LTI) using the RoX field spectrometer within the frame of the mDRONES4RIVERS project in the years 2019, 2020 and 2021 respectively. Measurement were recorded at the southern tip of the island Nonnenwerth in 2019 and 2020, over a side arm of the Rhine in Emmericher Ward 2019, 2020, 2021 (as Emmerich I) and in a ditch at the side arm in Emmericher Ward 2020 and 2021 (as Emmerich II) in Germany. LTI Nonnenwerth was investigating dewberry (Rubus caesius), LTI Emmerich I was investigating sediment dynamics and mixed pioneering vegetation and LTI Emmerich II was investigating mainly mixed pioneering vegetation. The incoming radiance is measured with optics of hemispherical (~180°) field of view and the reflected radiance with conical (~25°) field of view. Zip repositories contain folders named according to LTI place and year of recording. They include human radable .csv files for raw RoX data, calibrated radiance and reflectance in subfolders named after date of recording, a folder with time-lapse photographs of the footprint (only for Emmerich I and Emmerich II) and an ALL_INDEX file, each. For reflectance and radiance files, the first collumn contains the associated central wavelengths, the first row the time of recording, each subsequent field of the table contains the calibrated radiance (in W m-2 sr-1 nm-1) or reflectance (unitless) values. The ALL_INDEX file contains meta data, computed vegetation indices(VI) and quality flags for the time series.

Changes in dissolved organic matter and oxygen consumption in different bank filtration simulations at different scales

Both concentrations and compositions of dissolved organic matter (DOM) and the availability of oxygen affect transformation processes in close-to-nature drinking water treatments such as bank filtration and artificial groundwater infiltration. This study focused on quantitative and qualitative analyses of DOM in different saturated sand column systems of different dimensions, histories and operating conditions using fluorescence spectroscopy. The study revealed the presence of two fluorescent DOM (fDOM) fractions (humic-like compounds) through parallel factor analysis (PARAFAC). DOM, fDOM and specific UV absorbance (SUVA) at 254 nm were reduced and correlated in indoor systems. In outdoor columns, the removals of DOM and fDOM were comparably high, but the increased SUVA indicated an increase in aromaticity. Dissolved oxygen consumption corresponded to organic content in sand, independent of residence times. Overall, bank filtration is an effective option to remove biodegradable DOM under outdoor natural conditions. © Royal Society of Chemistry 2023

30 Jahre Messvergleich für natürliche Gammastrahlung

30 Jahre Messvergleich für natürliche Gammastrahlung ODL-Messgeräte bei Vergleichsmessungen Sie umgibt uns, wo wir gehen und stehen: Gammastrahlung aus dem Boden unter unseren Füßen. Für Anwendungen in Industrie, Medizin und Forschung kann sie auch künstlich erzeugt werden. Die Intensität von Gammastrahlung lässt sich mit sogenannten Ortsdosisleistungs-Messgeräten ( ODL -Messgeräten) erfassen. Viele dieser Geräte werden im Labor geprüft – mit Strahlungsquellen, die in der Natur nicht vorkommen. Werden ODL -Messgeräte speziell für das Bestimmen natürlicher Gammastrahlung eingesetzt, sollte zusätzlich ihre Eignung für diese Anwendungsarten getestet werden: zum Beispiel zum Prüfen des Sanierungserfolgs bei der Stilllegung von Bergbau- und Tagebauflächen oder beim Untersuchen von Baugrundstücken. Das Bundesamt für Strahlenschutz ( BfS ) bietet deswegen bereits seit drei Jahrzenten in Zusammenarbeit mit der Wismut GmbH auf diesen Zweck zugeschnittene Vergleichsmessungen zur Qualitätssicherung an. Das bundeseigene Unternehmen saniert und renaturiert die Hinterlassenschaften des Uranerzbergbaus in Sachsen und Thüringen. 40 Einrichtungen sind dabei Vom 20. bis 21. Juni 2023 nutzten etwa 40 Einrichtungen wie Behörden, Forschungsinstitute, Sachverständigenbüros und Unternehmen den nunmehr 30. Messvergleich des BfS für ODL -Messgeräte, um die Eignung ihrer Technik für die Erfassung natürlich auftretender Strahlung sowie die Messgenauigkeit ihrer Geräte zu überprüfen. Dabei mussten sich die Geräte beim Erfassen verschiedener Strahlungsintensitäten bewähren. Hierfür stellte die Wismut GmbH besonders präparierte Flächen auf einem Außengelände in Reust in der Nähe von Gera zur Verfügung. Zum Abschluss der Messungen zieht die Leiterin des Fachgebiets Dosimetrie und Spektrometrie im BfS , Nicole Klasen, eine positive Bilanz: "Gemeinsam mit der Wismut GmbH blicken wir auf drei Jahrzehnte erfolgreicher Zusammenarbeit zurück. Die jährlichen Vergleichsmessungen des BfS sind längst zu einer festen Institution geworden, die in Reust optimale Bedingungen vorfindet." Viele Teilnehmer*innen seien Stammgäste, die den Messvergleich nicht nur zur Prüfung ihrer Messgeräte, sondern auch für den fachlichen Austausch nutzten. "Sich zu vernetzen, andere Gerätetechnik und Vorgehensweisen kennenzulernen oder neue Kolleginnen und Kollegen von der eigenen Erfahrung profitieren zu lassen – all dies gehört ebenso zu Qualitätssicherung und Kompetenzerhalt im Strahlenschutz wie der reine Messvergleich" , betont Klasen. "Die Ortsdosisleistung ist ein wesentlicher Parameter zur Bewertung von radiologischen Situationen bei der Sanierung bergbaulicher Hinterlassenschaften" , erläutert Michael Paul, Geschäftsführer der Wismut GmbH . Umso wichtiger sei es, diese Messwerte qualitätsgesichert und mit geeigneten Messgeräten zu ermitteln. "Unsere über 30-jährige erfolgreiche Zusammenarbeit mit dem BfS hat dazu wichtige Voraussetzungen geschaffen." BfS verschickt Einzelergebnisse Für das BfS beginnt ein Großteil der Arbeit übrigens erst nach dem eigentlichen Messen. "Wir rechnen damit, dass weit über 3.000 Einzelmessungen zusammengekommen sind" , sagt Klasen. Wie viele es genau seien, werde man erst beim Auswerten der Messprotokolle sehen. Das Ergebnis der Auswertung werde im Anschluss an die Teilnehmenden verschickt. "Sie können daraus entnehmen, wie gut ihre Geräte bei der Messung der ODL abgeschnitten haben. Deutlich auffällige Werte können auch ein Hinweis darauf sein, dass das Messgerät für diesen Einsatzzweck nicht geeignet ist." Stand: 21.06.2023

Hubschrauber-Radiometrie (HRD)

Der BGR-Messhubschrauber (Sikorsky S-76B) wird zur aerogeophysikalischen Erkundung des Erduntergrundes eingesetzt. Das Standardmesssystem umfasst die Methoden Elektromagnetik, Magnetik und Radiometrie. Das passive Messsystem der Hubschrauber-Radiometrie (HRD) besteht aus einem Gammastrahlenspektrometer, das sich im Hubschraubers befindet. Der Detektor des Spektrometers hat fünf Natriumiodid-Kristalle (Volumen: 4 l pro NaI-Kristall). Gemessen wird das Spektrum der Gammastrahlung im Bereich von 0 bis 3 MeV. Als Ergebnis werden die Totalintensität und die (Äquivalent-) Gehalte von Thorium, Uran, Kalium sowie die Ionendosisleistung am Erdboden dargestellt.

Irlbach 2021 - An Agricultural Flight Campaign to prepare for Spaceborne Spectroscopy using the AVIRIS_NG Instrument

Abstract

Smart filters for the analysis of microplastic in beverages filled in plastic bottles

The occurrence of microplastic (MP) in food products, such as beverages in plastic bottles, is of high public concern. Existing analytical methods focus on the determination of particle numbers, requiring elaborate sampling tools, laboratory infrastructure and generally time-consuming imaging detection methods. A comprehensive routine analysis of MP in food products is still not possible. In the present work, we present the development of a smart filter crucible as sampling and detection tool. After filtration and drying of the filtered-off solids, a direct determination of the MP mass content from the crucible sample can be done by thermal extraction desorption gas chromatography mass spectroscopy (TED-GC/MS). The new filter crucible allows a filtration of MP down to particle sizes of 5 (micro)m. We determined MP contents below 0.01 (micro)g/L up to 2 (micro)g/L, depending on beverages bottle type. This may be directly related to the bottle type, especially the quality of the plastic material of the screw cap. Dependent on the plastic material, particle formation increases due to opening and closing operations during the use phase. However, we have also found that some individual determinations of samples were subjected to high errors due to random events. A conclusive quantitative evaluation of the products is therefore not possible at present. © Taylor&Francis Online

Molecular modelling of epoxy resin crosslinking experimentally validated by near-infrared spectroscopy

Reliable simulation of polymers on an atomistic length scale requires a realistic representation of the cured material. A molecular modeling method for the curing of epoxy systems is presented, which is developed with respect to efficiency while maintaining a well equilibrated system. The main criterion for bond formation is the distance between reactive groups and no specific reaction probability is prescribed. The molecular modeling is studied for three different mixing ratios with respect to the curing evolution of reactive groups and the final curing stage. For the first time, the evolution of reactive groups during the curing process predicted by the molecular modeling is validated with near-infrared spectroscopy data, showing a good agreement between simulation results and experimental measurements. With the proposed method, deeper insights into the curing mechanism of epoxy systems can be gained and it allows us to provide reliable input data for molecular dynamics simulations of material properties. © The Author(s)

Determination of microplastic mass content by thermal extraction desorption gas chromatography-mass spectrometry

The scientific and practical challenge of detecting microplastics (MPs) in the environment in a targeted and rapid manner is solved by innovative coupling of thermogravimetric analysis with mass spectrometric methods. Fast identification and quantitative determination of most thermoplastic polymers and elastomers is possible by using thermal extraction desorption gas chromatography-mass spectrometry (TED-GC-MS). © Authors

1 2 3 4 5185 186 187