API src

Found 13 results.

Entwicklung eines On-line Partikeldetektors

Das Projekt "Entwicklung eines On-line Partikeldetektors" wird vom Umweltbundesamt gefördert und von Universität Duisburg, Fachbereich 9 Elektrotechnik, Fachgebiet Prozess- und Aerosolmesstechnik durchgeführt. In semiconductor technology clean process gases must be provided to manufacture large scale integrated chips. To prevent micro contamination of wafers, the process gases must be controlled by on-line detection of suspended particles. In this project the on-line particle detection is realized by means of optical method. Due to the low particle concentration, the entire cross section of the gas pipe has to be controlled. Thus it is necessary to install an illuminating plane of over 32 mm2 perpendicularly to gas flow. In clean gases paricles down to 0,1 my m must be detected. In this size range molecule noise leads to False-Count-Rate. To reduce the F.C.R. an additional illuminating plane is arranged parallel to the original one, and the F.C.R. is decreased via anew Pipeline-Cross-Correlation-Function, which is developed in this project. Using this P.C.C.F. method the influence of molecule noise on particle detection can be strongly reduced, and detection becomes possible without any dead time. To create the illuminatingplanes non-imaging optical elements are used, where beam bend is caused by reflection and diffraction exclusively. Applying computer simulation, the optical characteristics of those non-imaging optics are investigated, and it is shown that the scattered light intensity is nearly independent on local position of detected particles in the plane. The application of the non-imaging optics leads to high precision combined with low manufacturing costs. The results of optical simulation show that the pre-condition to detected particles with non-condition to detected particles with non-imaging optics in clean process gases in fulfilled, i.e. the entire gas flow is controlled, and the low detection limit is expanded down to 0,1 micron and local dependence of detector is smaller than 4 percent within measuring volume 6,4 mm x 6,4 mm. The algorithm of P.C.C.F. is based on classical cross-correlation. The difference between them is that output result from P.C.C.F. is a function of real time, t, but not a function of delaying time, t, which corresponds to the time difference between the two signals. Therefore, it is possible to set P.C.C.F. in on-line measurement. To examine the efficiency of P.C.C.F., a particle signal mixed with two acquired noise are simulated on computer. The results of simulation show that, in output process of P.C.C.F., the noise is reduced and the level of particle signal becomes higher. The signal-noise reatio is improved from one to four.

Entwicklung eines Raman-Lidar-Geraetes zur Messung der Luftverunreinigung

Das Projekt "Entwicklung eines Raman-Lidar-Geraetes zur Messung der Luftverunreinigung" wird vom Umweltbundesamt gefördert und von Messerschmitt-Bölkow-Blohm durchgeführt. Ein gepulster Laserstrahl wird an gasfoermigen Verunreinigungen Raman-gestreut: Die gestreuten Photonen werden einzeln gezaehlt.

Signalverarbeitung fuer optische Partikelzaehler

Das Projekt "Signalverarbeitung fuer optische Partikelzaehler" wird vom Umweltbundesamt gefördert und von Universität Duisburg, Fachbereich 9 Elektrotechnik, Fachgebiet Prozess- und Aerosolmesstechnik durchgeführt. Optical particle counters (OPC) allow the determination of the particle number concentration and the size distribution. Instruments of different design are commercially available. One of the most important application areas of OPCs is clean technology. The development in clean technology is characterized by a drastic reduction in the allowed number concentration and the critical particle size which determines the lower size detection limit. With decreasing number concentration and decreasing lower detection limit the problem of false signals becomes more and more important. In the past a lot of effort has been put in redesigning the sensor of OPCs resulting in improved instrument behavior. Less effort has been put in improving the signal processing leading to a better SNR. Depending on the trigger level at a low SNR the particles might not be detected or the noise might cause false counts. The detection limit as well as the number of false pulses can be lowered by increasing the SNR. A higher amplification of the signal, thought as a possible solution, reduces the band width of the amplifier, which limits the flow rate. An additional effect caused by higher amplification may be that the noise level increases. If a flow false count rate is very important, the trigger level for detection has to be increased causing the instrument to become less sensitive. In this case the smallest detectable particle size increases. In this project a solution is worked out for optimizing the SNR for given OPCs. With the help of signal theory a correlation receiver was developed, which supplies a maximum SNR at the output. This receiver was realized in digital technology. It permits the on-line filtration of the particle signals for any commercial OPC. The results show a clear improvement in the SNR, which however, depends on the individual OPC. For a clean room monitor a gain of g gleich 2.06 gleich 6.28 dB was achieved, which means a reduction of the lower detection limit from 500 nm to a theoretical 421 nm with a constant false count rate. But the experiments have shown that it is possible to measure even 380 nm latex particles with security. With an unchanged lower detection limit false countings can be excluded with a security of more than plus minus 6 minus. On the whole it has been shown that in the field of optical particle measurement technology it is still absolutely possible to achieve considerable improvements and more research in the future is needed.

Automatische Zaehlung von Lymphozyten im Blut

Das Projekt "Automatische Zaehlung von Lymphozyten im Blut" wird vom Umweltbundesamt gefördert und von Bundesgesundheitsamt, Institut für Strahlenhygiene durchgeführt.

Geraete-Vorschlag: Entwicklung eines im Fliegen funktionierenden Fern-Erfassungs-In-Situ-Aerosol-Messsystems zum Einsatz in Stratosphaeren-Ballons oder Flugzeugen

Das Projekt "Geraete-Vorschlag: Entwicklung eines im Fliegen funktionierenden Fern-Erfassungs-In-Situ-Aerosol-Messsystems zum Einsatz in Stratosphaeren-Ballons oder Flugzeugen" wird vom Umweltbundesamt gefördert und von Johannes Gutenberg-Universität Mainz, Institut für Physik der Atmosphäre durchgeführt. The scientific tasks of the project are: 1) to measure in-situ particle size distributions; 2) to determine in thermodynamical phase of the particles; 3) to obtain the optical particle refractive index; 4) to measure the particle shapes (especially in cirrus and PSC type I and II clouds); 5) to measure the distribution of particles in space (especially the structure of leewave-induced PSCs); 6) to derive total particulate surface for studies of heterogeneous chemistry; 7) to compute optical extinction due to the aerosol and other optical data relevant for the data reduction of the LIDAR operated by both participants on the platform; 8) to study in detail the physics underlying the scattering of light by aerosol particles by application of Mie theory; 9) to use a microphysical box model together with the stratospheric data. ARIAS is an integrated instrument of two components: 1) Laser Scatterometer - for remote sensing measurements in the near range of the airborne platform (ie several hundred meters around Perseus, Geophysika or stratospheric balloon). 2) Optical Particle Counter - for in-situ analysis of individually sampled aerosol particles.

Untersuchung des Rauschverhaltens von optischen Partikelzaehlern

Das Projekt "Untersuchung des Rauschverhaltens von optischen Partikelzaehlern" wird vom Umweltbundesamt gefördert und von Universität Duisburg, Fachbereich 9 Elektrotechnik, Fachgebiet Prozess- und Aerosolmesstechnik durchgeführt. In many production systems and in research the measurement of particles gains more and more importance. With increasing technological advances smaller particles will gain importance. The areas which require reduced particle concentration are for example the semiconductor industry, the food production and the medicine technique. For particle measurements optical particle counters are often used. To fulfil the requirements these particle counters have to be improved. Goals are obtaining an enhancement of the accuracy of size analysis, a higher security of counting and a reduction of the detection limit with regards to the particle diameter. These demands can be met with the improvement of the signal processing. The signal processing of optical particle counters must detect the particle signal in the composite signal. The composite signal consits of the noise and the particle signal. The limit of the particle detection is set by the particle concentration and by the noise. The noise in the signal affects the signal processing in different ways. The amplitudes of the particle signals are stochastically falsified and it results in a wider particle frequency distribution. If the amplitude of the noise is greater than the threshold then the noise is counted as a particle. This effect occurs near the lower detection limit regarding to the particle diameter. To improve the signal detection a digital signal processing has to be developed which uses the features of the composite signal to minimise the signal to noise ratio. The essential condition for this development is to characterise the composite signal. The magnitudes are described with their moments of the distribution. The noise consists of - the noise of the electronics - the scattering light from molecules and - the scattered light from surfaces. The noise of the electronics has mostly thermal sources. The scattering light of molecules interacts with the molecules in the measuring cell. The number of molecules are function of the temperature, the gas species and the pressure. The scattered light from surfaces is produces from the lighttrap and the optics. The characteristics in the distributions of the noise and the particle signals, which are the same in all optical particle counters, have to be investigated. To detect the characteristics of the noise in optical particle counters the parameters temperature, gas species, pressure and the surface must be varied. With the investigation of the noise behaviour a digital signal processing system which improves the optical particle counter can be developed.

Einfluss des Brechungsindex auf die Messgenauigkeit von optischen Teilchenzaehlern

Das Projekt "Einfluss des Brechungsindex auf die Messgenauigkeit von optischen Teilchenzaehlern" wird vom Umweltbundesamt gefördert und von Ludwig-Maximilians-Universität München, Meteorologisches Institut durchgeführt. Berechnung der Messgenauigkeit von optischen Teilchenzaehlern mit Hilfe der mie-Theorie; Abhaengigkeit vom Brechungsindex der Aerosolteilchen.

Erosion und Resuspension von Mineralpartikeln in einem Windkanal

Das Projekt "Erosion und Resuspension von Mineralpartikeln in einem Windkanal" wird vom Umweltbundesamt gefördert und von Universität Mainz, Fachbereich Physik, Institut für Meteorologie durchgeführt. Aride Gebiete der Erde tragen mit ihrer Emission von weit ueber 1000 x 1000000 Tonnen von Mineralstaub wesentlich zum Haushalt des atmosphaerischen Aerosols bei. Dabei werden erhebliche Anteile des Mineralstaubes interkontinental verfrachtet, so dass diese Aerosolkomponente global von klimatischer Bedeutung ist. Der Quellmechanismus (Erosion und Resuspension) als Funktion des Windfeldes und der Bodenzusammensetzung ist dabei nur sehr wenig untersucht. In dieser Studie soll versucht werden, den Teilchenfluss der Mineralpartikel im Submicronbereich mit Hilfe eines optischen Teilchenzaehlers unter kontrollierten Bedingungen bezuegl. Windgeschwindigkeit und Groessenverteilung des Bodenmaterials in einem Windkanal zu messen. Eben diese Partikelfraktion bestimmt die atmosphaerische Truebung und geht darueberhinaus in den Ferntransport mit Distanzen bis zu mehr als 5000 km.

Charakterisierung von ultrafeinen Partikeln für den Arbeitsschutz - Toxikologie ultrafeiner Partikeln

Das Projekt "Charakterisierung von ultrafeinen Partikeln für den Arbeitsschutz - Toxikologie ultrafeiner Partikeln" wird vom Umweltbundesamt gefördert und von Universität Gießen, Medizinisches Zentrum für Ökologie, Institut und Poliklinik für Arbeits- und Sozialmedizin durchgeführt. Tierexperimente zeigen, daß der Vorschlag der DFG einer Erfassung nur der ultrafeinen Partikeln kleiner 200 nm nicht ausreicht, um die Gefährdung durch ultrafeine Stäube am Arbeitsplatz adäquat abzuschätzen. Vielmehr müssen für eine vollständige Charakterisierung zusätzlich die alveolengängigen Aggregate und Agglomerate erfaßt und hinsichtlich ihrer Biobeständigkeit, d.h. sowohl bezüglich des Zerfalls in Primärteilchen als auch der Löslichkeit, bewertet werden. Weiterhin ist zu prüfen, in welcher Menge mechanisch erzeugte Stäube ultrafeine Partikeln im Vergleich mit technisch wichtigen reinen U-Aerosolen (Rauchen) besitzen, bzw. unter welchen Umständen diese vernachlässigt werden können. Eine derartig umfassende Analyse kann prinzipiell mit der hochauflösenden analytischen Rastertransmissionselektronenmikroskopie (ARTEM) im Verbund mit gravimetrischen Verfahren erfolgen. Untersucht werden sollen Schweißrauche als wichtiges Paradigma ultrafeiner Aerosole im Vergleich zu Dieselruß, Carbon Black und durch mechanische Bearbeitung erzeugten Gesteinsstäuben. Luftprobenahmen sollen zunächst an den Prüfständen des Instituts für Gefahrstoffforschung (IGF) der Bergbau - Berufsgenossenschaft, Bochum, erfolgen. Bestimmt werden soll hierbei sowohl die Massenkonzentration der einatembaren (E) als auch der alveolengängigen (A) Fraktion sowie insbesondere die Teilchenkonzentration im Vergleich von ARTEM-Analyse und simultanen Messungen der ultrafeinen (U) Fraktion mit einem Kondensationskeimzähler mit vorgeschaltetem Differentialmobilitätsanalysator (Scanning mobility particle sizer, SMPS von TSI). Später sollen weitere Luftprobenahmen an Arbeitsplätzen, und zwar an ca. 10 Schweißerarbeitsplätzen beim Elektro-, Autogen- und Schutzgasschweißen sowie an je 2 Arbeitsplätzen mit Dieselrußemission und Carbon Black und an einem Arbeitsplatz bei der Bearbeitung von Natursteinen erfolgen. Für eine ARTEM-Analyse unmittelbar an den beaufschlagten Filtern (direkte Präparation) sind kurzzeitige Probenahmen erforderlich, die eine auswertbare Filterbelegung gewährleisten, so daß Primärteilchen, Aggregate und Agglomerate noch einzeln differenzier- und analysierbar sind. Bei längerer Probenahme wird die Filterbeaufschlagung in wäßrige Suspension überführt, aus der dann in einer Verdünnungsreihe weitere Filter beaufschlagt werden können (indirekte Präparation).

Entwicklung eines Streulichtmessverfahrens zur Partikelgroessenanalyse in Gasstroemungen

Das Projekt "Entwicklung eines Streulichtmessverfahrens zur Partikelgroessenanalyse in Gasstroemungen" wird vom Umweltbundesamt gefördert und von Technische Universität Clausthal, Institut für Mechanische Verfahrenstechnik und Umweltverfahrenstechnik durchgeführt. Streulicht-Partikelzaehlgeraete zur Bestimmung der Konzentration und Groessenverteilung von Partikeln besitzen Arbeitsabstaende in der Groessenordnung von Millimetern. Messungen in stroemenden Gasen sind daher nur in Wandnaehe moeglich. Eine weitere Begrenzung dieser Geraete liegt in dem engen erfassbaren Partikelgroessenbereich. Aus diesen Gruenden sind eine Reihe von Messaufgaben - insbesondere in der Heissgasentstaubung - bisher nicht loesbar. Das Vorhaben dient der Entwicklung eines Streulicht-Partikelzaehlgeraetes mit einem Arbeitsabstand von bis zu 200 mm und einem grossen, simultan erfassbaren Partikelgroessenbereich von 0,15 mym bis 20 mym. Ermoeglicht wird diese Entwicklung durch den Einsatz eines Lasers mit zwei verschiedenen Lichtwellenlaengen, eines neuartigen Mikroskop-Teleobjektivs und Fortschritte bei der fuer die Auswertung erforderliche numerische Loesung von Integralgleichungen.

1 2